Deviations from specified pressure in boundary condition PressureNonEquilibriumCompressible on the GPU
The boundary condition PressureNonEquilibriumCompressible does not set the correct pressure in the GPU version:
We can see this when comparing the GPU results of the app LaminarPipeFlow to the CPU results:
Even though the deviations of the pressure are small, the velocity in the LaminarPipeFlow app is incorrect in the GPU version.
Edited by Anna Wellmann