Skip to content

Deviations from specified pressure in boundary condition PressureNonEquilibriumCompressible on the GPU

The boundary condition PressureNonEquilibriumCompressible does not set the correct pressure in the GPU version:

We can see this when comparing the GPU results of the app LaminarPipeFlow to the CPU results: 20240117_LaminarPipe_density_gpu 20240117_LaminarPipe_density_cpu

Even though the deviations of the pressure are small, the velocity in the LaminarPipeFlow app is incorrect in the GPU version. 20240117_LaminarPipe_velocity_gpu 20240117_LaminarPipe_velocity_cpu

Edited by Anna Wellmann